Station 7 — Sicily Island: QC report

ULM_Stn7 · CR1000X s/n 58340 · table FiveMin · file header program CPU:SO397545_Univ_of_LA_Measonet_Rev09282026.Stn7.wndcor.CR1X
2026-11-12 06:00 to 2026-11-19 05:55 logger clock · generated 2026-11-19 03:56
2,016unique 5-min records
0values flagged failure
0values flagged suspect
0dated corrections applied

Sensor heights: 10-m prop (WS/WindDir_30ft), 10-m sonic (WS/WindDir_Sonic), 2-m prop (WS/WindDir_10ft); Temp 2 m EE181 (AirTF), Temp 10 m T109 (T109_30ft), Temp 0.5 m T109 (T109_10ft). Column names keep the logger program's old labels.

Station-level findings

leveltestfinding
infotemperature_profileTemp 0.5 m minus Temp 2 m: +2.6 F on sunny light-wind afternoons, -1.6 F on calm nights (normal near-ground layering)
infosolar_timingoverall solar timing offset +0 min over 6 clear days (positive = later than expected)
infopressure_elevationthe logger reduces pressure to sea level as if the barometer were at 71 ft; stations.yaml says 72 ft
infolsm_neighborsLSM neighbors: 8 (34 km), 32 (41 km), 16 (48 km), 12 (51 km)
infosunny_calm_tmaxafternoon high on sunny light-wind days -0.4 F vs LSM neighbors (5 days)
infohumidity_vs_lsmtoo few well-mixed hours in the last 30 days to compare humidity with 8 (34 km), 32 (41 km), 16 (48 km), 12 (51 km)
infofile_summary3045 rows read (last 7 days), 2016 unique records, 2026-11-12 06:00:00 to 2026-11-19 05:55:00 (logger clock)
inforecord_resetRECORD reset 14204 -> 0 (program load or table reset)
infowind_direction_periodwind directions checked from 2026-09-28 08:39 (logger clock): program Rev09282026 and later Rev10012026 with the current alignment (PropAz 325, SonicAz 325, Off10 0); earlier directions are left out
infosoil_failed_reads9 SoilVUE depth readings were all zeros (failed SDI-12 read): set to missing

Wind direction

By logger-program period (vs airports, after applied corrections)

Measured offset W = 325°. Predicted 10-m prop rotation with no correction code = 180 − W; with the sign-flipped line = 360 − 2W.

period (logger clock)records10-m prop10-m sonic2-m propif no codeif sign-flippedbest explanation
2026-11-12 06:00 to 2026-11-16 15:201,265–––-145°+70°not explained
2026-11-16 15:25 to 2026-11-19 05:55751–––-145°+70°not explained

Flags by variable and month

Comparison with nearby LSM stations

Humidity sensor vs nearby LSM stations

info too few well-mixed hours in the last 30 days to compare humidity with 8 (34 km), 32 (41 km), 16 (48 km), 12 (51 km)

Compared with Stn 8 (34 km), Stn 32 (41 km), Stn 16 (48 km), Stn 12 (51 km). Dewpoint is compared rather than RH because the air's moisture varies little between nearby sites when the air is mixed, while RH also swings with each site's temperature (warm coastal nights, cold hollows).

Temperature by height (0.5, 2 and 10 m)

Wind speed ratios and solar timing

Power: battery, solar charging and load

Last 7 daysthis stationnetwork / expected
Overnight battery minimum12.66 V12.76 V
Lowest battery reading12.58 V
Charged in / used per day3.5 / 2.3 Ah
Reached full charge (float)7:30 am7:30 am
Solar input, sunny-day peak21.9 V~21 V
Overnight draw0.094 A
Charger temperature max26 °C
Charger minus logger voltage+0.09 Vwire drop
CH200 readings missing0.0%

Logger and communications health (daily)

11-1611-1711-18
Logger lithium battery (V)0.003.693.68
Logger resets (watchdog)00
Skipped 5-min measurements00
Low 12 V events00
Cell signal RSRP (dBm)-75-76-75
Cell signal quality RSRQ (dB)-11-10-10
Cell data use (KB)799979997999
BaroVUE quality (avg)6.596.626.63
Sonic invalid (% of readings)0.00.00.0
RainVUE failed reads (%)0.000.000.00
BaroVUE / CH200 / SoilVUE failed reads (of 288)0 / 0 / 00 / 0 / 00 / 0 / 0
Rain gauge tilt (°, avg)
Rain gauge tilt (°, max - mast sway)1.01.01.0
RainVUE lithium battery (V)0.003.103.12
Pyranometer tilt (°, avg)
Pyranometer tilt (°, max - mast sway)3.33.94.5
Pyranometer heater on (h)0.00.30.2
Power-saving time (h)0.00.00.0

Flag counts by test

None.

Largest failure events

None.

Corrections

Applied (from stations.yaml):

None.

Documented but not applied (apply: false):

None.

How to read this

Levels: 0 good, 1 suspect, 2 failure, 9 missing. Each variable's level is in QC_<variable> in the data file; the events file lists every flagged run with the test that set it. Station-level findings summarize patterns (sensor rotation, clock offsets, duplicate soil depths) that per-record flags can't describe on their own. Wind direction flags use daily vector means, so a flagged day marks every record in that day.