Station 32 — St Joseph: QC report

ULM_Stn32 · CR1000X s/n 59180 · table FiveMin · file header program CPU:SO397545_Univ_of_LA_Measonet_Rev09282026.Stn32.wndcor.CR1X
2026-09-28 05:55 to 2026-10-05 05:50 logger clock · generated 2026-10-05 03:50
2,015unique 5-min records
10values flagged failure
9,549values flagged suspect
0dated corrections applied

Station-level findings

leveltestfinding
suspectdirection_vs_other_sensors30ft-10ft: median daily difference +24 deg over 7 days
suspectdirection_vs_other_sensors10ft-sonic: median daily difference -22 deg over 7 days
infosolar_timingoverall solar timing offset +2 min over 4 clear days (positive = later than expected)
infolsm_neighborsLSM neighbors: 7 (41 km), 21 (60 km), 8 (69 km), 11 (74 km)
infofile_summary5013 rows read (last 7 days), 2015 unique records, 2026-09-28 05:55:00 to 2026-10-05 05:50:00 (logger clock)
infofiles_combinedrecord combined from 2 files: ULM_Stn32_FiveMin.dat.backup (2026-09-17 to 2026-09-28, SO397545 Univ of LA Measonet Rev03262026.Stn32.wndcor.CR1X); ULM_Stn32_FiveMin.dat (2026-09-28 to 2026-10-05, SO397545_Univ_of_LA_Measonet_Rev09282026.Stn32.wndcor.CR1X)
inforecord_resetRECORD reset 40317 -> 0 (program load or table reset)
infogap1 missing records after 2026-09-28 09:45:00

Wind direction

By logger-program period (vs airports, after applied corrections)

Measured offset W = 203°. Predicted 30-ft rotation with no correction code = 180 − W; with the sign-flipped line = 360 − 2W.

period (logger clock)records30-ftsonic10-ftif no codeif sign-flippedbest explanation
2026-09-28 09:55 to 2026-10-05 05:451,967–––-23°-46°not explained

Flags by variable and month

Comparison with nearby LSM stations

Temperature sensor agreement

Wind speed ratios and solar timing

Power: battery, solar charging and load

Last 7 daysthis stationnetwork / expected
Overnight battery minimum12.82 V12.84 V
Lowest battery reading12.81 V
Charged in / used per day5.2 / 2.5 Ah
Reached full charge (float)8:10 am8:20 am
Solar input, sunny-day peak20.6 V~21 V
Overnight draw0.103 A
Charger temperature max39 °C
Charger minus logger voltage+0.09 Vwire drop
CH200 readings missing0.0%

Flag counts by test

variable test level records % of record
SoilTmpF_100cm_Avg range failure 1 0.05
SoilTmpF_10cm_Avg range failure 1 0.05
SoilTmpF_20cm_Avg range failure 1 0.05
SoilTmpF_30cm_Avg range failure 1 0.05
SoilTmpF_40cm_Avg range failure 1 0.05
SoilTmpF_50cm_Avg range failure 1 0.05
SoilTmpF_5cm_Avg range failure 1 0.05
SoilTmpF_60cm_Avg range failure 1 0.05
SoilTmpF_75cm_Avg range failure 1 0.05
T109_10ft_F_Avg temperature_triad failure 1 0.05
BulkEC_5cm_Avg soil_air_gap suspect 1944 96.48
Ka_5cm_Avg soil_air_gap suspect 1944 96.48
VWC_5cm_Avg soil_air_gap suspect 1944 96.48
WindDir_30ft_D1_WVT direction_vs_other_sensors suspect 1152 57.17
WindDir_Sonic_D1_WVT direction_vs_other_sensors suspect 1152 57.17
WindDir_10ft_D1_WVT direction_vs_lsm_neighbors suspect 576 28.59
WindDir_10ft_D1_WVT direction_vs_neighbors suspect 576 28.59
T109_10ft_F_Avg temperature_triad suspect 405 20.10
WindDir_30ft_D1_WVT direction_vs_neighbors suspect 216 10.72
WindDir_Sonic_D1_WVT direction_vs_neighbors suspect 216 10.72

Largest failure events

start (local) end (local) n variable test detail
2026-09-28 09:55 2026-09-28 09:55 1 SoilTmpF_100cm_Avg range outside hard limits [10, 125]
2026-09-28 19:55 2026-09-28 19:55 1 T109_10ft_F_Avg temperature_triad differs from other two temperature sensors by > 10.0 F

Corrections

Applied (from stations.yaml):

None.

Documented but not applied (apply: false):

None.

How to read this

Levels: 0 good, 1 suspect, 2 failure, 9 missing. Each variable's level is in QC_<variable> in the data file; the events file lists every flagged run with the test that set it. Station-level findings summarize patterns (sensor rotation, clock offsets, duplicate soil depths) that per-record flags can't describe on their own. Wind direction flags use daily vector means, so a flagged day marks every record in that day.