Station 31 — Baton Rouge: QC report

ULM_Stn31 · CR1000X s/n 59185 · table FiveMin · file header program CPU:SO397545_Univ_of_LA_Measonet_Rev09282026.Stn31.wndcor.CR1X
2026-09-28 05:55 to 2026-10-05 05:50 logger clock · generated 2026-10-05 03:50
2,016unique 5-min records
305values flagged failure
1,847values flagged suspect
0dated corrections applied

Station-level findings

leveltestfinding
infosolar_timingoverall solar timing offset +12 min over 2 clear days (positive = later than expected)
infolsm_neighborsLSM neighbors: 36 (29 km), 19 (49 km), 28 (57 km), 37 (69 km)
infofile_summary5014 rows read (last 7 days), 2016 unique records, 2026-09-28 05:55:00 to 2026-10-05 05:50:00 (logger clock)
infofiles_combinedrecord combined from 2 files: ULM_Stn31_FiveMin.dat.backup (2026-09-17 to 2026-09-28, SO397545 Univ of LA Measonet Rev03052026.Stn31.wndcor.CR1X); ULM_Stn31_FiveMin.dat (2026-09-28 to 2026-10-05, SO397545_Univ_of_LA_Measonet_Rev09282026.Stn31.wndcor.CR1X)
inforecord_resetRECORD reset 40317 -> 0 (program load or table reset)

Wind direction

By logger-program period (vs airports, after applied corrections)

Measured offset W = 291°. Predicted 30-ft rotation with no correction code = 180 − W; with the sign-flipped line = 360 − 2W.

period (logger clock)records30-ftsonic10-ftif no codeif sign-flippedbest explanation
2026-09-28 09:50 to 2026-10-05 05:451,968+25°+12°–-111°+138°not explained

Proposed corrections (not applied; copy into stations.yaml to use):

sensor start end add apply reason
30ft 2026-09-28 09:50 2026-10-05 05:45 -25 False empirical (median vs reference); observed +25 deg (airports)

Flags by variable and month

Comparison with nearby LSM stations

Temperature sensor agreement

Wind speed ratios and solar timing

Power: battery, solar charging and load

Last 7 daysthis stationnetwork / expected
Overnight battery minimum12.82 V12.84 V
Lowest battery reading12.80 V
Charged in / used per day4.4 / 2.7 Ah
Reached full charge (float)10:45 am8:20 am
Solar input, sunny-day peak20.6 V~21 V
Overnight draw0.118 A
Charger temperature max41 °C
Charger minus logger voltage+0.08 Vwire drop
CH200 readings missing0.0%

Flag counts by test

variable test level records % of record
RV_Pre_Accu_Tot sensor_missing failure 2016 100.00
WindDir_30ft_D1_WVT direction_vs_neighbors failure 288 14.29
WindDir_30ft_D1_WVT stuck_direction failure 4 0.20
WindDir_30ft_SD1_WVT stuck_direction failure 4 0.20
SoilTmpF_100cm_Avg range failure 1 0.05
SoilTmpF_10cm_Avg range failure 1 0.05
SoilTmpF_20cm_Avg range failure 1 0.05
SoilTmpF_30cm_Avg range failure 1 0.05
SoilTmpF_40cm_Avg range failure 1 0.05
SoilTmpF_50cm_Avg range failure 1 0.05
SoilTmpF_5cm_Avg range failure 1 0.05
SoilTmpF_60cm_Avg range failure 1 0.05
SoilTmpF_75cm_Avg range failure 1 0.05
BattV_Avg late_full_charge suspect 864 42.86
WindDir_30ft_D1_WVT direction_vs_lsm_neighbors suspect 576 28.57
WindDir_30ft_D1_WVT direction_vs_neighbors suspect 576 28.57
T109_10ft_F_Avg temperature_triad suspect 293 14.53
WindDir_30ft_D1_WVT direction_vs_other_sensors suspect 288 14.29
T109_30ft_F_Avg temperature_triad suspect 113 5.61
SlrW_Avg solar_above_clearsky suspect 1 0.05

Largest failure events

start (local) end (local) n variable test detail
2026-09-28 05:55 2026-10-05 05:50 2016 RV_Pre_Accu_Tot sensor_missing rain gauge (RainVUE): no readings (100% of a 24-h window blank) while the station is reporting: cable, connector, SDI-12 address/port, or sensor
2026-10-04 00:00 2026-10-04 23:55 288 WindDir_30ft_D1_WVT direction_vs_neighbors daily direction differs from neighbor stations by > 60 deg
2026-09-28 08:30 2026-09-28 08:45 4 WindDir_30ft_D1_WVT stuck_direction direction SD = 0 with wind >= 3.0 mph
2026-09-28 09:50 2026-09-28 09:50 1 SoilTmpF_100cm_Avg range outside hard limits [10, 125]

Corrections

Applied (from stations.yaml):

None.

Documented but not applied (apply: false):

None.

How to read this

Levels: 0 good, 1 suspect, 2 failure, 9 missing. Each variable's level is in QC_<variable> in the data file; the events file lists every flagged run with the test that set it. Station-level findings summarize patterns (sensor rotation, clock offsets, duplicate soil depths) that per-record flags can't describe on their own. Wind direction flags use daily vector means, so a flagged day marks every record in that day.